What Safety Or Building Standards Does My Property Have To Meet To Be Licensed As An STR?

While not a full guide of standards, the Park City Nightly Rentals application lists the following as things on the inspection checklist:
- Smoke alarm in each bedroom, hallway outside of bedroom area and on each floor level.
- Carbon monoxide detector in hallway outside of bedroom area and on each floor level.
- Handrail on stairs with four or more risers.
- Guardrails on decks and walking surfaces 30" or more above the ground or floor.
- Each bedroom shall have an emergency escape and rescue opening, i.e., a door that opens directly outside, or at least one window meeting all the following: min. opening area of 5.7 square feet, opening width of 20" and height of 24" and bottom sill not more than 44" above the floor.
- Tempered glass in windows located in hazardous locations.
- Adequate sanitary facilities.
- GFCI protected outlets in kitchen and within 6 feet of bathroom sinks, bathtubs, and hot tubs.
- Extension cords used as outlets, or a power strip connected to an extension cord are prohibited.
- Gas appliances in sleeping areas are prohibited without specific modifications. Call us for details.
- Fire extinguisher (Type 2A:10BC) with location signage. Tagged as serviced within the last year.
- Water heaters (WH) & furnaces (F):
- (WH) Approved straps, on top third and bottom third of tank. Expansion tank also strapped.
- (WH & F) Sticker showing it is de-rated for altitude.
- (WH & F) Proper venting and gas connections. (WH) installs post 2012 must have 4" vents.
- (WH & F) Minimum 36" clearance in front of heater/combustion chamber.
- All hot tub motors/heaters shall be GFCI protected. Hot tubs in a residential building with more than two dwelling units shall have a single shutoff switch within 5' to 50' away.
- Common area emergency exit lighting and exit signs function on building power and on backup battery power (where applicable).
- Common area fire extinguishers are serviced and tagged annually (where applicable).
- Provide a copy of the following reports to the inspector (where applicable):
- Single family fire riser/sprinkler system inspected and tagged annually.
- Current copy of elevator "Utah State Certification of Inspection and Permit to Operate" (public use only).
- Common area fire riser/sprinkler systems are inspected and tagged annually.
- Common area fire riser/sprinkler systems have a 5-year hydrostatic test.
- Common area fire alarm system has been tested and serviced annually.
NOTE: Common area items apply to multi-family residential buildings (i.e., condominiums, hotels, etc.).